GD Hex-core Meshing

GD Hex-core Meshing combines a hexahedral core, body-fitted near-wall regions and polyhedral fill cells that connect regions with different shapes and resolution. It is designed to preserve useful resolution near complex surfaces while keeping large, less demanding parts of the domain efficient.

The hexahedral core covers the bulk flow. Boundary layers concentrate cells normal to walls where velocity and temperature gradients matter. Polyhedral fill cells connect these regions and accommodate geometric transitions. This combination provides flexibility around complex geometry without requiring fine cells everywhere.

Why this helps

Surface detail, wall-normal resolution and wake refinement can be controlled for their different purposes. A carefully planned mesh can capture important gradients with fewer total cells than a uniformly refined domain. High cell quality and an appropriate distribution both matter: a clean quality histogram cannot compensate for an unresolved boundary layer or wake.

Use mesh-sensitivity and solution evidence to demonstrate efficiency for your case. No universal cell-count reduction or accuracy gain is implied.

Configure by engineering intent

The public request selector is engine="octree_prism"; the product name is GD Hex-core Meshing. For external flow, octree_prism.controls provides compact controls for flow direction, orientation, surface fidelity, domain size, wake refinement, local refinement and wall layers. The service resolves the requested intent into a validated mesh configuration.

Start with inspected geometry bounds and units, the operating speed and the required wall treatment. Use plan_mesh for supported external-flow planning, inspect the proposed request, then validate and estimate it before submission. A plan does not run a mesh.

Important recent capabilities

Named surfaces and STEP solid names support targeted refinement and boundary selection. Local refinement can follow parts or geometric regions, and wake controls place resolution downstream of the physics that generates it. Boundary layers can use explicit first-cell height or a target wall-resolution estimate. Multi-region STEP workflows support explicit fluid/solid assemblies, including supported layered configurations.

Read surfaces, refinement, boundary layers and CHT meshing before combining these controls. The accepted combination depends on the workflow; external-flow controls do not automatically apply to CHT.

Review the delivered mesh

Use the saved quality report and CGNS mesh, not only the preview. Inspect cell count, positive volumes, quality distributions, boundary coverage, layer continuity, wake coverage and region identity. Count misses can enter awaiting_decision; accept or discard that saved candidate explicitly before continuing.