Spatial accuracy controls

Spatial reconstruction, gradients and limiters affect how Fluxcore represents changes between cells. Their useful setting depends on mesh quality and the flow being resolved. Increasing nominal order cannot compensate for unresolved gaps, walls or wakes.

Use get_solver_controls with queries such as muscl, limiter or gradient, filtered to the selected simulation type. The returned canonical names belong under config.compressible_config. Validate the complete request because some combinations are restricted.

Engineering procedure

Start from automatic defaults. Establish a stable baseline with inspected mesh quality and meaningful force or heat-transfer monitors. Change the desired accuracy control, then compare residual histories, physical bounds and the quantity of interest. Use mesh and time-step sensitivity to separate discretization effects from insufficient resolution.

For DES/DDES, inspect whether the wake and time sampling can resolve the fluctuations of interest. For CHT, review wall and material-interface resolution as well as fluid gradients. Preserve the exact request and result qualification when comparing cases.

Detailed construction algorithms, proprietary progression policies and implementation-specific recovery mechanisms are not part of this public guide. The supported public control contract is discoverable through advanced controls.