MCP_prepare_cold_plate_simulation_FluxCoreConfigΒΆ

Generated from the central API contract. Availability and permissions are checked by the connected service.

Field

Type / accepted values

Required

Default

Constraints / meaning

simulation_type

"rans" / "urans" / "cht"

No

"rans"

architecture

"fluxcore" / "workhorse" / "krylov"

No

"fluxcore"

Use the live schema and the applicable workflow guide for semantics.

mesh_format

"cgns" / "openfoam"

No

"cgns"

mesh_scale_factor

number

No

1.0

exclusiveMinimum: 0; Stored meshes are in meters. A different scale requires an explicit mesh_unit_conversion on the simulation request; OpenFOAM always requires 1.0.

airspeed

number

No

0.0

minimum: 0; Freestream speed in m/s; zero is not a substitute for a missing operating point.

angle_of_attack

number

No

0.0

Angle of attack in degrees.

reference_pressure

number

No

101325.0

exclusiveMinimum: 0; Reference absolute pressure in Pa.

temperature

number

No

300.0

exclusiveMinimum: 0; Freestream absolute temperature in K.

fluid

Fluid

No

Omitted

boundary_conditions

object

No

Omitted

turbulence_model

"k_omega_sst" / "spalart_allmaras" / "laminar"

No

"k_omega_sst"

wall_treatment

"wall_functions" / "low_re" / "none"

No

"wall_functions"

max_iterations

integer or null

No

6000

minimum: 1; maximum: 1000000; Steady iteration ceiling; explicitly null for URANS.

convergence_tolerance

number

No

1e-06

exclusiveMinimum: 0; exclusiveMaximum: 1

export_solution_fields

boolean

No

true

time_step

number or null

No

null

exclusiveMinimum: 0; URANS physical time step in seconds; supply an engineering time scale.

n_physical_steps

integer or null

No

null

minimum: 1; maximum: 1000000

inner_iterations

integer or null

No

null

minimum: 1; maximum: 10000

bdf_order

integer or null

No

null

minimum: 1; maximum: 2; URANS backward-difference time order; resolved default 2.

bdf_startup_steps

integer or null

No

null

minimum: 0; maximum: 1000000

inner_chunk_size

integer or null

No

null

minimum: 1; maximum: 10000

inner_residual_drop

number or null

No

null

exclusiveMinimum: 0

inner_cfl

number or null

No

null

Use the live schema and the applicable workflow guide for semantics.

inner_early_stop

boolean or null

No

null

transient_predictor

"previous" / "extrapolate" or null

No

null

transient_washout_steps

integer or null

No

null

minimum: 0; maximum: 1000000

transient_sample_steps

integer or null

No

null

minimum: 0; maximum: 1000000

iterations_per_output

integer or null

No

null

minimum: 0; maximum: 1000000; Output cadence in iterations/physical steps; 0 disables intermediate output, not final export.

live_history_interval

integer

No

50

minimum: 1; maximum: 100

forces

MCP_prepare_cold_plate_simulation_ForcesConfig or null

No

null

mrf_zones

array of MCP_prepare_cold_plate_simulation_MRFZone

No

Omitted

maxItems: 64; Multiple reference frames tied to actual mesh cell zones; rotating walls alone do not define a rotating fluid zone.

thermal

MCP_prepare_cold_plate_simulation_ThermalConfig or null

No

null

cht_inlet_temperature

number or null

No

null

exclusiveMinimum: 0; CHT inlet temperature in K.

cht_turbulent_prandtl

number or null

No

null

exclusiveMinimum: 0

compressible_config

MCP_prepare_cold_plate_simulation_NumericalControls or null

No

null

Use the live schema and the applicable workflow guide for semantics.

Omission and explicit null are different. Defaults shown are schema defaults; validators may resolve conditional defaults or reject incompatible combinations. See the workflow guide and validate the complete request before submission.