Thermal request exampleΒΆ
This request illustrates laminar CHT with a fluid region named coolant and a solid named plate. Replace all identities and physical properties with verified data for your mesh and operating point. The values below are illustrative constants, not a qualified material model.
{
"mesh_artifact_id": "REPLACE_WITH_MESH_ARTIFACT_ID",
"config": {
"architecture": "fluxcore",
"simulation_type": "cht",
"turbulence_model": "laminar",
"wall_treatment": "none",
"fluid": {"density": 997.0, "viscosity": 0.00089, "molecular_weight": 18.015},
"cht_inlet_temperature": 298.15,
"boundary_conditions": {
"inlet": {"type": "inlet", "value": {"velocity": [1, 0, 0], "temperature": 298.15}},
"outlet": {"type": "outlet", "value": {"pressure": 101325}},
"walls": {"type": "wall"}
},
"thermal": {
"fluid_zone_names": ["coolant"],
"solid_zone_names": ["plate"],
"k_per_zone": {"coolant": 0.6, "plate": 200},
"rho_per_zone": {"coolant": 997, "plate": 2700},
"cp_per_zone": {"coolant": 4180, "plate": 900},
"heat_source_w_per_zone": {"plate": 100},
"inlet_patch": "inlet",
"outlet_patch": "outlet",
"reference_temperature": 298.15
},
"export_solution_fields": true
}
}
Validate with POST /v1/simulations/validate or validate_simulation, estimate, and submit only after confirming region assignments and the intended operating regime. Structural validation does not establish that a particular coolant/material combination is qualified for the connected solver or that the assumed laminar regime is appropriate.
Use ThermalConfig for field types and thermal modelling for units, coupling controls and energy-balance checks. surface_heat_sources are a separate supported load definition with explicit zone and footprint geometry; see SurfaceHeatSource.