FlowRegionΒΆ

Generated from the central API contract. Availability and permissions are checked by the connected service.

Field

Type / accepted values

Required

Default

Constraints / meaning

kind

"external" / "internal" / "solid"

No

"external"

external: fluid outside bodies; internal: selected fluid volume; solid: material inside a selected closed component, with no fluid region.

minimum_mm

array [number, number, number] or null

No

Omitted

minItems: 3; maxItems: 3

maximum_mm

array [number, number, number] or null

No

Omitted

minItems: 3; maxItems: 3

component_id

string or null

No

Omitted

maxLength: 120; Existing profile component ID for internal fluid or solid-only meshing; never infer an ID from a display name.

boundary_names

map of string

No

Omitted

Omission and explicit null are different. Defaults shown are schema defaults; validators may resolve conditional defaults or reject incompatible combinations. See the workflow guide and validate the complete request before submission.