FluxCoreConfig

Generated from the central API contract. Availability and permissions are checked by the connected service.

Field

Type / accepted values

Required

Default

Constraints / meaning

simulation_type

"rans" / "urans" / "cht"

No

"rans"

architecture

"fluxcore" / "workhorse" / "krylov"

No

"fluxcore"

Use the live schema and the applicable workflow guide for semantics.

mesh_format

"cgns" / "openfoam"

No

"cgns"

mesh_scale_factor

number

No

1.0

exclusiveMinimum: 0.0; Stored meshes are in meters. A different scale requires an explicit mesh_unit_conversion on the simulation request; OpenFOAM always requires 1.0.

airspeed

number

No

0.0

minimum: 0.0; Freestream speed in m/s; zero is not a substitute for a missing operating point.

angle_of_attack

number

No

0.0

Angle of attack in degrees.

reference_pressure

number

No

101325.0

exclusiveMinimum: 0.0; Reference absolute pressure in Pa.

temperature

number

No

300.0

exclusiveMinimum: 0.0; Freestream absolute temperature in K.

fluid

Fluid

No

Omitted

boundary_conditions

object

No

Omitted

turbulence_model

"k_omega_sst" / "spalart_allmaras" / "laminar"

No

"k_omega_sst"

wall_treatment

"wall_functions" / "low_re" / "none"

No

"wall_functions"

max_iterations

integer or null

No

6000

minimum: 1.0; maximum: 1000000.0; Steady iteration ceiling; explicitly null for URANS.

convergence_tolerance

number

No

1e-06

exclusiveMinimum: 0.0; exclusiveMaximum: 1.0

export_solution_fields

boolean

No

true

time_step

number or null

No

Omitted

exclusiveMinimum: 0.0; URANS physical time step in seconds; supply an engineering time scale.

n_physical_steps

integer or null

No

Omitted

minimum: 1.0; maximum: 1000000.0

inner_iterations

integer or null

No

Omitted

minimum: 1.0; maximum: 10000.0

bdf_order

integer or null

No

Omitted

minimum: 1.0; maximum: 2.0; URANS backward-difference time order; resolved default 2.

bdf_startup_steps

integer or null

No

Omitted

minimum: 0.0; maximum: 1000000.0

inner_chunk_size

integer or null

No

Omitted

minimum: 1.0; maximum: 10000.0

inner_residual_drop

number or null

No

Omitted

exclusiveMinimum: 0.0

inner_cfl

number or null

No

Omitted

Use the live schema and the applicable workflow guide for semantics.

inner_early_stop

boolean or null

No

Omitted

transient_predictor

"previous" / "extrapolate" or null

No

Omitted

transient_washout_steps

integer or null

No

Omitted

minimum: 0.0; maximum: 1000000.0

transient_sample_steps

integer or null

No

Omitted

minimum: 0.0; maximum: 1000000.0

iterations_per_output

integer or null

No

Omitted

minimum: 0.0; maximum: 1000000.0; Output cadence in iterations/physical steps; 0 disables intermediate output, not final export.

live_history_interval

integer

No

50

minimum: 1.0; maximum: 100.0

forces

ForcesConfig or null

No

Omitted

mrf_zones

array of MRFZone

No

Omitted

maxItems: 64; Multiple reference frames tied to actual mesh cell zones; rotating walls alone do not define a rotating fluid zone.

thermal

ThermalConfig or null

No

Omitted

cht_inlet_temperature

number or null

No

Omitted

exclusiveMinimum: 0.0; CHT inlet temperature in K.

cht_turbulent_prandtl

number or null

No

Omitted

exclusiveMinimum: 0.0

compressible_config

NumericalControls or null

No

Omitted

Use the live schema and the applicable workflow guide for semantics.

Omission and explicit null are different. Defaults shown are schema defaults; validators may resolve conditional defaults or reject incompatible combinations. See the workflow guide and validate the complete request before submission.

Compatibility identity selectors are intentionally omitted from this reading view. Leave them unset. The connected service’s complete schema and solver-control discovery remain authoritative; do not manufacture substitute parameter names.